Hi, Obviously, it is total energy treshold. Please have a look at /Doc/INPUT_PW in your Espresso directory. As a sequence, it is not the same as tolwfr and tolvrs in ABINIT.
Bests, Eyvaz. --- "Nichols A. Romero" <naromero at gmail.com> wrote: > Hi, > Where can I find the definition of the conv_thr > parameter? > Is this a tolerance on the the wavefunction squared > or potential residual ( > i.e. analagous to tolwfr or tolvrs in ABINIT)? > I searched the pw_forum archive but could not find > a useful reference. > Thanks, > -- > Nichols A. Romero, PhD. > 1613 Denise Dr. Apt. D > Forest Hill, MD 21050 > (217) 417-5210 > __________________________________________________ Do You Yahoo!? Tired of spam? Yahoo! Mail has the best spam protection around http://mail.yahoo.com