As discussed just about a week ago, the HSE version implemented in QE is HSE06: http://www.democritos.it/pipermail/pw_forum/2011-May/020690.html
For changing the screening parameter, there is an input parameter called 'screening_parameter' in system (default=0.106). For changing the fraction of the exact exchange, use 'exx_fraction' also in system (default=0.25). I guess these are not documented anywhere in the official distribution... Best regards, Hannu-Pekka Komsa EPFL, Switzerland > Dear all > > I would like to ask is it possible for user to change the screening > parameters in HSE method. > > The version I used is 4.2. currently, I noticed the screening parameter > is 0.106, that would corresponding to the HSE03 (if I'm correct). > I want to use HSE06, so, can I change this parameter to 0.11? If yes, > could some tell me how to set it? I can't find the one control the > screening parameter. > > Thank you > > regards > Maofeng