I would not use mp smearing with a zero dos(Ef) metal like graphene... 
m-v or even gaussian should give more reliable results.
the reason is that m-p smearing is not positive definite leading to 
spurious negative densities if the k-point sampling is not  good enough 
... whichi, I guess, will never be  with graphene.

stefano

meysam pazoki wrote:
> Dear pwscf users
>
> Thanks for the answers.As I said,I See the honeycomb structure in xcrysden.
>  I dont know what is wrong, I have attached the .in file.
>
> Thanks  for considering my question
> Regards
> meysam Pazoki
> PhD. student of physics
> sharif university of technology
>
>   
> ------------------------------------------------------------------------
>
> _______________________________________________
> Pw_forum mailing list
> Pw_forum at pwscf.org
> http://www.democritos.it/mailman/listinfo/pw_forum
>   

Reply via email to