the namelists are read in a specific order: &ions must come before &cell stefano
? ?? wrote: >Dear members, >I got a little problem on "vc-relax" issue.This is >part of input file below: > > &CONTROL > calculation = 'vc-relax' , > restart_mode = 'from_scratch' , > outdir = >'/home/max/espresso-3.0/tmp/' , > pseudo_dir = >'/home/max/espresso-3.0/pseudo/' , > prefix = 'sc0.001' , > tstress = .true. , > tprnfor = .true. , > / > &SYSTEM > ibrav = 0, celldm(1) =6.62, > nat = 4, ntyp = 2, ecutwfc = 64.0, > occupations='smearing', >smearing='gaussian',degauss=0.01 > / > &ELECTRONS > conv_thr = 1.0d-8 , > mixing_mode = 'plain' , > mixing_beta = 0.7 , > diagonalization = 'cg' , > / >&CELL > cell_dynamics = "damp-w", >/ >&IONS > pot_extrapolation = "second_order", > wfc_extrapolation = "second_order", >/ >CELL_PARAMETERS {hexagonal} > 1.000000000 0.000000000 0.000000000 > -0.500000000 0.866025404 0.000000000 > 0.000000000 0.000000000 1.609000000 > > >But output file showed that: > > >%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% > from read_namelists : error # 1 > reading namelist cell > >%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% > >So what I missing setup (necessary) in namelist cell >?(I had try several settings but got the same error >message above) > >max > > > > >___________________________________________________ > ??????? ? ???????????????? > http://messenger.yahoo.com.tw/ >_______________________________________________ >Pw_forum mailing list >Pw_forum at pwscf.org >http://www.democritos.it/mailman/listinfo/pw_forum > >