Dear pwscf user, Recently, I calculated Bilayer graphene with vdw correction. In version of 4.3, the parameter of London can be set to 'true' and then add vdw correction to Exc. In version of 5.1, more options can do it, such as, 'grimmer-d2', 'dft-d'. However, many tests have been performed but I cannot get the layer-distance (3.34 angstrom in experiment). I uesd GGA-PBE and LDA-PZ with vdw, recepetively. The final results shows small distance (3.0 angstrom). I donnot know why leads to the small distance. So, I still tested the Ecut (30Ry-60Ry0) and vaccum (10-20 angstrom), but the problem was the same. The input file is,
&CONTROL calculation = 'relax' , outdir ='./tmp' , restart_mode = 'from_scratch' , pseudo_dir ='/home/plgong/pseudo', etot_conv_thr = 1.0e-4 , forc_conv_thr = 1.0e-3 , prefix='graphene', / &SYSTEM ibrav = 4, a =2.46 c =10.0 nat = 4, ntyp = 1, ecutwfc = 30.D0 , ecutrho = 240.0 , vdw_corr='grimme-d2' tot_charge = 0.00, occupations = 'smearing' , degauss = 0.02 , smearing='mv' / &ELECTRONS conv_thr = 1.D-7 , mixing_beta=0.3 mixing_mode='local-TF' electron_maxstep=300 / &IONS ion_dynamics = 'bfgs' , / ATOMIC_SPECIES C 12.00000 C.pz-rrkjus.UPF ATOMIC_POSITIONS {crystal} C 0.000000 0.000000 0.500000 C 0.333333 0.666667 0.500000 C 0.000000 0.000000 0.834000 C 0.666667 0.333333 0.834000 K_POINTS {automatic} 30 30 1 0 0 0 Can anyone help me to solve it? P. L. Gong ISSP CAS, HeFei, China -- ==================================================== Addr: Institute of Solid State Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, China Tel: +86-551-65591591(office), 18756086113(cell phone) Email: plg...@theory.issp.ac.cn ======================================================================== _______________________________________________ Pw_forum mailing list Pw_forum@pwscf.org http://pwscf.org/mailman/listinfo/pw_forum