Dear Rajkamal, In the cp .evp file, the last column (11th column) is the time step and the 4th column is the Temperature column. For position, You need to go to the * .pos* file and from there you can extract position. After that you can plot the time step from .evp file and position from .pos file.
Regards, Shashi Shashi Bhusan Mishra Research Scholar, Dept. Of Physics, IIT Madras , Chennai -36