Several possibilities - simplest is that the SCF calculation is done with a coarse mesh, and the top of the valence and/or the bottom of the conduction are not located at points on this mesh.

[BTW, they do not need to be located, either, along the path you chose to plot the band strcture]

Try with a mterials that has a direct band gap at Gamma, using unshifted sampling meshes (e.g. 6 6 6 0 0 0)

nicola

On 28/08/2019 19:46, MARIA CATERINA CEVALLOS BRENES wrote:
Dear QE developers and users:

I was computing the band gaps from scf calculations as the difference between HOMO and LUMO energies. Nonetheless, when I perform the bands' calculation and plot the band structure I notice this band gap is a lot less than the one I computed initially (with scf).

Am I doing something wrong? Or what am I exactly computing when I take the HOMO LUMO difference in the scf-calculation.

Thank you very much!

Caterina Cevallos,

University of Costa Rica.


_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu/quantum-espresso)
users mailing list users@lists.quantum-espresso.org
https://lists.quantum-espresso.org/mailman/listinfo/users



--
----------------------------------------------------------------------
Prof Nicola Marzari, Chair of Theory and Simulation of Materials, EPFL
Director, National Centre for Competence in Research NCCR MARVEL, EPFL
http://theossrv1.epfl.ch/Main/Contact http://nccr-marvel.ch/en/project
_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu/quantum-espresso)
users mailing list users@lists.quantum-espresso.org
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to