Dear Abdul,

starting_magnetization is the initial ratio of the number of polarized 
electrons to the total number of valence electrons for the respective atomic 
species. Therefore, it ranges from –1.0 (all spins down) through 0.0 (paired 
spins) to +1.0 (all spins up). It is used to construct the first guess for the 
wave function, but the magnetic configuration will likely change during the 
self-consistent optimization.
Your particular case apparently converged to one given result regardless of the 
initial magnitude of the homogeneously distributed magnetic moment, but 
starting_magnetization is generally able to affect the resulting wave function; 
e.g., you can often force the system to end up in a ferromagnetic state, in a 
non-magnetic state, or in one of several different anti-ferromagnetic states 
with a varied distribution of spin-up and spin-down atoms in the lattice.
In addition to starting_magnetization, there is the tot_magnetization keyword, 
defining the total magnetization of the simulation cell, fixed during the 
entire calculation.

The reason why the sum of magnetic moments per site is smaller than the total 
magnetization is, indeed, the fact that the spheres do not fill the entire 
simulation cell.

Hope that helps.

Martin Matas
University of West Bohemia
Czech Republic


 Čtvrtek, Únor 15, 2024 10:19 CET, Abdul Muhaymin via users 
<users@lists.quantum-espresso.org> napsal:

> Hello QE users,
> 
> I am trying to understand how to appropriately set the starting_magnetization 
> value and how to interpret the output related to magnetization in the pw.x. I 
> tested for a simple system (BCC Fe) with various starting_magnetization and 
> observed that it doesn't matter. The total energy, total magnetization, and 
> absolute magnetization values remain the same. So, does this mean any 
> starting_magnetization value can be used?
> 
> Secondly, when I observe the "Magnetic moment per site (integrated on atomic 
> sphere of radius R)" values, and sum up all the magnetic moments, it doesn't 
> match with the total magnetization or absolute magnetization which is 
> reported at the end (in Bohr mag/cell). The sum of magnetic moment per site 
> is always less than the sum of total magnetization. What could be the reason 
> for this? Is this because magnetic moment per site is integrated on atomic 
> sphere of radius R where R < 1?
> 
> Sincerely,
> Abdul Muhaymin,
> Graduate(MS) Student, Institute of Materials Science and Nanotechnology,
> Bilkent University, Ankara.

_______________________________________________
The Quantum ESPRESSO community stands by the Ukrainian
people and expresses its concerns about the devastating
effects that the Russian military offensive has on their
country and on the free and peaceful scientific, cultural,
and economic cooperation amongst peoples
_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list users@lists.quantum-espresso.org
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to