Dear Experts,

I hope this message finds you well.

I am currently performing a variable cell relaxation (vc-relax) calculation for 
Li2S6. However, I keep encountering the error message: "Not enough space 
allocated for radial FFT: try restarting with a larger cell_factor." According 
to the documentation, the recommended values for cell_factor during the pw.x 
execution are 2 or 1. Despite trying both values, the error persists. 
Interestingly, when I set cell_factor to 3, the calculation proceeds without 
any issues.

Could you please advise if setting the cell_factor to 3 is appropriate for 
pw.x, or if there might be an underlying issue with my parameters?

Thank you for your time and assistance.

Best regards,
Bill Guo

Attachment: in.in
Description: in.in