Dear Experts, I hope this message finds you well.
I am currently performing a variable cell relaxation (vc-relax) calculation for Li2S6. However, I keep encountering the error message: "Not enough space allocated for radial FFT: try restarting with a larger cell_factor." According to the documentation, the recommended values for cell_factor during the pw.x execution are 2 or 1. Despite trying both values, the error persists. Interestingly, when I set cell_factor to 3, the calculation proceeds without any issues. Could you please advise if setting the cell_factor to 3 is appropriate for pw.x, or if there might be an underlying issue with my parameters? Thank you for your time and assistance. Best regards, Bill Guo
in.in
Description: in.in
_______________________________________________ The Quantum ESPRESSO community stands by the Ukrainian people and expresses its concerns about the devastating effects that the Russian military offensive has on their country and on the free and peaceful scientific, cultural, and economic cooperation amongst peoples _______________________________________________ Quantum ESPRESSO is supported by MaX (www.max-centre.eu) users mailing list [email protected] https://lists.quantum-espresso.org/mailman/listinfo/users
