Dear Iurii,

Thank you for your reply. As you guessed, I used ‘ortho-atomic’ during Hubbard 
projectors. If we do not use this one, which one is suggested?

Best regards,
Yifeng Zhao

发件人: users <[email protected]> 代表 
[email protected] 
<[email protected]>
日期: 星期日, 2025年5月11日 03:08
收件人: [email protected] <[email protected]>
主题: users Digest, Vol 214, Issue 10

Send users mailing list submissions to
        [email protected]

To subscribe or unsubscribe via the World Wide Web, visit
        https://lists.quantum-espresso.org/mailman/listinfo/users
or, via email, send a message with subject or body 'help' to
        [email protected]

You can reach the person managing the list at
        [email protected]

When replying, please edit your Subject line so it is more specific
than "Re: Contents of users digest..."


Today's Topics:

   1. Re: The long time takes in calculation of Computing stress
      and pressure during vc-relax (Timrov Iurii)


----------------------------------------------------------------------

Message: 1
Date: Sat, 10 May 2025 16:47:46 +0000
From: Timrov Iurii <[email protected]>
To: "[email protected]"
        <[email protected]>
Subject: Re: [QE-users] The long time takes in calculation of
        Computing stress and pressure during vc-relax
Message-ID:
        
<zr0p278mb026667fe4436ad76b818adabee...@zr0p278mb0266.chep278.prod.outlook.com>

Content-Type: text/plain; charset="us-ascii"

Dear Zhao,

Which type of Hubbard projectors are you using for PBE+U calculations? Since 
the calculation of Hubbard forces and stresses takes a lot of time, then most 
likely you are using "ortho-atomic" Hubbard projectors. It is well known that 
the calculations of Hubbard forces and stresses are slow when using this type 
of projectors. You can check the paper where it is explained why this is so: 
https://journals.aps.org/prb/abstract/10.1103/PhysRevB.102.235159

Greetings,
Iurii

----------------------------------------------------------
Dr. Iurii TIMROV
Tenure-track scientist
Laboratory for Materials Simulations (LMS)
Paul Scherrer Institut (PSI)
CH-5232 Villigen, Switzerland
+41 56 310 62 14
https://www.psi.ch/en/lms/people/iurii-timrov
________________________________
From: users <[email protected]> on behalf of Zhao 
Yi-Feng <[email protected]>
Sent: Saturday, May 10, 2025 08:15
To: [email protected] <[email protected]>
Subject: [QE-users] The long time takes in calculation of Computing stress and 
pressure during vc-relax

Dear quantum-espresso developer and user,

I am using quantum-espresso to do the cell relaxation with vc-relax. The system 
is a supercell that contains 96 spin-polarized atoms (AFM) using PBE+U. It is 
fast for the first SCF calculation, which costs about 30 minutes to converge. 
However, it takes about 3.5 hours to calculate the stress (Cartesian axis) and 
pressure. I am not sure what happened to this issue. Could anyone help me with 
this? Thank you

Best regards,
Zhao
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://lists.quantum-espresso.org/pipermail/users/attachments/20250510/3d02da9e/attachment-0001.html>

------------------------------

Subject: Digest Footer

_______________________________________________

The Quantum ESPRESSO community stands by the Ukrainian
people and expresses its concerns about the devastating
effects that the Russian military offensive has on their
country and on the free and peaceful scientific, cultural,
and economic cooperation amongst peoples.
_______________________________________________
Quantum ESPRESSO is supported by MaX 
(www.max-centre.eu<http://www.max-centre.eu>)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users

------------------------------

End of users Digest, Vol 214, Issue 10
**************************************
_______________________________________________________________________________
The Quantum ESPRESSO Foundation stands in solidarity with all civilians 
worldwide who are victims of terrorism, military aggression, and indiscriminate 
warfare.
--------------------------------------------------------------------------------
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list [email protected]
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to