I don't think I ran any ant files.

I just unzipped the source into my project source directory probably,
unzipped the view handler into my source, resolved any compilation
errors by adding sitemesh dependency jars, then you have to rengister
the viewhandler in your faces config.

 

I don't have the project in front of me right now.  I'll look at the
project tonight.

 

Shawn

 

________________________________

From: Bobby Rosenberger [mailto:[EMAIL PROTECTED] 
Sent: Friday, December 14, 2007 2:05 PM
To: MyFaces Discussion
Subject: Re: Has anybody integrated Sitemesh+JSF/Tomahawk?

 

Hey Shawn,

 

I tried, unsuccessfully, to get his working. I'm certain I'm missing
something simple, because I see where you posted saying you got it
working using the same version numbers of everything that I use.

 

The part of the directions that seems to have more steps than indicated
was: "+ You can drop the unzipped folder in sitemesh source folder and
do a rebuild."
 

I downloaded the source code for sitemesh, and dropped the climbingrose
stuff in the sitemesh/src directory and ran the sitemesh ant build
script... the climbingrose stuff was not included. I assume some changes
have to be made to the build.xml? 

Or have I gone down the wrong path altogether? If I move the
climbingrose stuff into the sitemesh/src/java directory I get compile
errors... 

 

Any words of wisdom for me?

 

Thanks,

Bobby


 

        De: Garner, Shawn [mailto:[EMAIL PROTECTED] 
        Enviado el: Wednesday, December 12, 2007 9:15 AM
        Para: MyFaces Discussion; MyFaces Development 
        Asunto: RE: Has anybody integrated Sitemesh+JSF/Tomahawk?

         

        Check this out if you want to use sitemesh:

        http://jira.opensymphony.com/browse/SIM-201

         



-----Message Disclaimer-----

This e-mail message is intended only for the use of the individual or
entity to which it is addressed, and may contain information that is
privileged, confidential and exempt from disclosure under applicable law.
If you are not the intended recipient, any dissemination, distribution or
copying of this communication is strictly prohibited. If you have
received this communication in error, please notify us immediately by
reply email to [EMAIL PROTECTED] and delete or destroy all copies of
the original message and attachments thereto. Email sent to or from the
Principal Financial Group or any of its member companies may be retained
as required by law or regulation.

Nothing in this message is intended to constitute an Electronic signature
for purposes of the Uniform Electronic Transactions Act (UETA) or the
Electronic Signatures in Global and National Commerce Act ("E-Sign")
unless a specific statement to the contrary is included in this message.

While this communication may be used to promote or market a transaction
or an idea that is discussed in the publication, it is intended to provide
general information about the subject matter covered and is provided with
the understanding that The Principal is not rendering legal, accounting,
or tax advice. It is not a marketed opinion and may not be used to avoid
penalties under the Internal Revenue Code. You should consult with
appropriate counsel or other advisors on all matters pertaining to legal,
tax, or accounting obligations and requirements.

Reply via email to