Yuriy Demchenko:
Hi,

is there any way to edit iSCSI storage domain: change/add targets ? (lun, id, sn and actual content wouldn't be affected) Without VM export/import process - downtime should be as little as possible.

I'm researching possibility to use oVirt in env where I have only FC storage, connected to 2 servers (and sadly, second server will be available later, hence my question about changing targets in oVirt) and bunch of blades, on which i would like to run virtualization (no fc storage connectivity) - so idea is to share storage via iSCSI/tgtd and use multipathd with failover mode to protect from storage
I am not sure if the multipathd can recognize the FC path to the storage when the second server is available and regards it as the same as the iSCSI path used before. If it is not, I think the device under /dev/mapper may change when you cut the iSCSI path off and then enable FC path. That will definitely corrupt the meta data of the volume group which the storage domain is sitting on and the storage domain will be corrupted finally.

corruption.



--
---
舒明 Shu Ming
Open Virtualization Engineerning; CSTL, IBM Corp.
Tel: 86-10-82451626  Tieline: 9051626 E-mail: shum...@cn.ibm.com or 
shum...@linux.vnet.ibm.com
Address: 3/F Ring Building, ZhongGuanCun Software Park, Haidian District, 
Beijing 100193, PRC


_______________________________________________
Users mailing list
Users@ovirt.org
http://lists.ovirt.org/mailman/listinfo/users

Reply via email to