On Mon, Dec 1, 2014 at 5:26 PM, Chris Adams <c...@cmadams.net> wrote:
> Once upon a time, Gianluca Cecchi <gianluca.cec...@gmail.com> said: > > Am I missing anyting simple? > > Yep... > > > On the server offering iSCSI target: > > # tgtadm --lld iscsi --mode target --op show > > Target 1: iqn.2014-07.local.localdomain:store1 > > LUN: 1 > > SCSI ID: p_iscsi_store1_l > > LUN: 2 > > SCSI ID: p_iscsi_store1_l > > Both LUNs have the same ID name, which confuses discovery (I've done the > same thing before). This is a 16 character string, so make sure they > are distinct/unique in that 16 characters. > > It is annoying that scsi-target-utils lets you do this. > -- > Chris Adams <c...@cmadams.net> > _______________________________________________ > Users mailing list > Users@ovirt.org > http://lists.ovirt.org/mailman/listinfo/users > Arghhh! Actually the name I used is p_iscsi_store1_lun1 p_iscsi_store1_lun2 and the problem so should be that it is trimmed to 16 chars... I will try Thanks!!
_______________________________________________ Users mailing list Users@ovirt.org http://lists.ovirt.org/mailman/listinfo/users