On Mon, Dec 1, 2014 at 5:26 PM, Chris Adams <c...@cmadams.net> wrote:

> Once upon a time, Gianluca Cecchi <gianluca.cec...@gmail.com> said:
> > Am I missing anyting simple?
>
> Yep...
>
> > On the server offering iSCSI target:
> > # tgtadm --lld iscsi --mode target --op show
> > Target 1: iqn.2014-07.local.localdomain:store1
> >         LUN: 1
> >             SCSI ID: p_iscsi_store1_l
> >         LUN: 2
> >             SCSI ID: p_iscsi_store1_l
>
> Both LUNs have the same ID name, which confuses discovery (I've done the
> same thing before).  This is a 16 character string, so make sure they
> are distinct/unique in that 16 characters.
>
> It is annoying that scsi-target-utils lets you do this.
> --
> Chris Adams <c...@cmadams.net>
> _______________________________________________
> Users mailing list
> Users@ovirt.org
> http://lists.ovirt.org/mailman/listinfo/users
>

Arghhh!
Actually the name I used is
p_iscsi_store1_lun1
p_iscsi_store1_lun2

and the problem so should be that it is trimmed to 16 chars... I will try

Thanks!!