You usually have to specify that the LUN has to be accessible to
multiple systems (e.g. like a clustered filesystem would). It's not
unusual for a system to default to allowing only one initiator to connect.
On 10/02/2018 05:51 AM, Bernhard Dick wrote:
Hi,
I'm trying to achieve iSCSI multipathing with an Dell Compellent SC4020
array. As the Dell Array does not work as an ALUA system it displays
available LUNs only on the currently active system (here is a good
description that I found:
https://niktips.wordpress.com/2016/05/16/dell-compellent-is-not-an-alua-storage-array/
). As a result I cannot add the currently non-active controller to an
iSCSI-Bond (as it does not present the LUNs to oVirt) and so the path to
the second controller will not be up. Is there any way to solve this?
Regards
Bernhard
_______________________________________________