Hi, I have 4.1 cluster with FC block storage and hosted engine. Last night a 
host went unreachable due to a driver/firmware issue with the NIC card. The 
Engine spotted this, the host was fenced and everything behaved as expected. 
However, it got me thinking - if the affected host had been the one running the 
Engine, what would have happened? I'm assuming the Engine would have failed 
liveness check on the other hosted engine hosts and they would attempt to start 
the Engine. But as the "failed" host still had access to the storage (I believe 
the HBA was still working) then they would not be able to get a lock on the 
storage. In which case I'm in a catch-22, the Engine cannot fence the failed 
host because its network is isolated, but the Engine cannot be restarted else 
where until the failed host is fenced. At this point it requires human 
intervention to fence the failed host. Is my understanding correct on this? If 
so is there any way to mitigate this risk? Thanks, Alan