oVirt’s “Multipath” isn’t real iSCSI MPIO. It only works when all portals are 
reachable in the same L2 network, which defeats the usual design where each 
path sits on its own interface/subnet. That’s why adding extra paths through 
the UI feels inconsistent.

The stable approach is to expose both Ceph gateways as separate iSCSI 
connections and let the host initiator handle multipath. oVirt reuses the first 
connection created during HE deployment, so later storage domains inherit its 
portal and credentials.

https://pingmynetwork.com/network/ccna-200-301/lacp-etherchannel