Thank you,Neel

2018-05-20 2:52 GMT+08:00 Neel Pandeya <neel.pand...@ettus.com>:

> Hello Jong:
>
> I think Robin answered this in a separate thread with you, so I'm just
> responding to conclude this thread.
>
> The behavior that you describe is a result of a corrupted bit in the AVR
> EEPROM firmware that results in the power-on sequence requiring the power
> button to be pushed. This corruption can occur when power is abruptly
> removed from the device, instead of powering it down cleanly. The most
> straightforward way to resolve this issue is to RMA your E313. The latest
> revision of the E313 always powers on when power is applied, and ignores
> the state of the power button.
>
> --​Neel Pandeya
>
>
>
>
> On 3 May 2018 at 00:50, liu Jong via USRP-users <
> usrp-users@lists.ettus.com> wrote:
>
>> Hi all,
>> We know that when we insert network cable to e313,the e313 will power on
>> and press power button is not needed. Now,we take DC power supply(12V) for
>> e313,and we must press power button of e310 and then power on.
>> It is normal?How can we achieve power on and no press power button with
>> DC power supply for e313?
>>
>> thank you.