Hi Julián,
I am also getting these same errors and have been unsuccessful getting WR
working on either 3.15 or 4.0.  I have asked this list to see if anyone is
presently using WR successfully, but have not had any replies.  I know that
Ettus is presently looking into WR issues.
Rob


On Thu, May 6, 2021 at 8:57 AM Burella Pérez Julián Mariano <
[email protected]> wrote:

> Hello,
>
> We have a setup where we're trying to sync a N320 (bitstream WX) using
> White rabbit with a OPNT Timing Switch as Master configured as Free Running
> Master.
>
>
> +------------------------+                        +---------------------+
> |                                 |             SFP0  |
>          |
> | OPNT Timing Switch   |---------------- |        N320             |
> |                                 |                        |
>                |
> +------------------------+                        +---------------------+
>
>
> We are trying to run test program `test_pps_input` in order to see if PPS
> is working as expected.
> When running without any argument, the PPS is correctly detected, I
> suppose it is because it uses as time source `internal`.
> Then when I try to use `sfp0` as a time source, I observed 2 different
> behaviors:
>
> Command run: ./test_pps_input
> --args="clock_source=internal,time_source=sfp0" --source=sfp0
>
> 1. I get the following message:
>
> [ERROR] [RPC] TDC Failed to reset.
> [INFO] [MPM.Rhodium-0.init.LMK04828] LMK initialized and locked!
> [ERROR] [MPM.Sync-0] TDC Failed to Reset! Check your clocks! Status: 0x0
> [ERROR] [MPM.RPCServer] init() failed with error: TDC Failed to reset.
> Error: RuntimeError: Error during RPC call to `init'. Error message: TDC
> Failed to reset.
>
> And after this message, the PPS led does not blink anymore.
>
> 2.
> If I then run again the test after failing previously, this time I don't
> get any error message but a exception is thrown because no PPS was detected.
>
> We know that the OPNT Timing switch works when used with a OPNT node,
> where we get PPS and 10MHz signals.
>
> Do you think that there could be an issue when N320 and OPNT Switch try to
> sync together, or do you have any idea of what I could explore ?
>
> Thank you in advance for any help you can provide me with.
>
> Best,
> Julián
> _______________________________________________
> USRP-users mailing list -- [email protected]
> To unsubscribe send an email to [email protected]
>
_______________________________________________
USRP-users mailing list -- [email protected]
To unsubscribe send an email to [email protected]

Reply via email to