Have a look at your st.conf. I have a MSL 6030, and it attaches to the FC via a built in SCSI/FC router. That router presents the tape drives as LUN's 1 & 2, with the controller as LUN 0.
By default, the solaris st only scans LUN 0, but that can be changed in ST conf. Regards, Tristan. -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Song, Young Sent: Thursday, 11 May 2006 4:33 AM To: 'veritas-bu@mailman.eng.auburn.edu' Subject: [Veritas-bu] Sg / sgen driver issue I'm trying to set up Sun Fire-480R as a new backup server to replace an old one and in a situation where I'm stuck and thus want to ask here. I'm running Solaris 8 with all the latest Solaris patches including st driver patch, etc. & latest SAN Foundation Kit 4.4.9. And I have a FC-attached HP MSL 5060 library with 2 LTO-1 drives via Brocade Silkworm switches. After installing NetBackup v5.1, I tried following the steps in MediaMgr_DeviceConfig_Guide.txt but no matter what I tried, I couldn't have it see both tape drives properly and I believe it's something to do with sg.conf, sg.links, & devlink.tab files. However, I may be wrong. I tried all I could try with cfgadm, devfsadm, luxadm, zoning, etc. and know that I have all the proper connections and the box can see the library itself but not all the drives. Anyone experienced similar things and have any advice? Thank you in advance!!! - Young _______________________________________________ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu _______________________________________________ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu