You could on the old master: do one catalogbackup, then delete all the devices, and do second catalogbackup(to disk. And use the last catalogbackup for recovery on the new master.. and then set up devices like it should be.
I've done this successfully on an numerous sites. Not from W2000 to W2003 though... Anders -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of WEAVER, Simon (external) Sent: 26. november 2008 07:13 To: VERITAS-BU@mailman.eng.auburn.edu Subject: Re: [Veritas-bu] Moving to new master Sounds like some sort of inconsistency. Not sure what your plan is to move to a new master - Are you using bprecover to restore everything back to the new platform? Ideally, it's be better to restore everything to the new hardware, using the same OS/NetBackup revisions from the previous master. Either that, or delete and rebuild the global database. As I said, to me; sounds like something is out of sync. There is a section in the NetBackup Disaster Recovery plan about using the bprecover and restoring the catalogs. Remember, retaining the same IP / Server Name / OS / NetBackup / Patch Level is essential to the success of this. Simon -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of venkatesh111 Sent: Tuesday, November 25, 2008 11:16 PM To: VERITAS-BU@mailman.eng.auburn.edu Subject: [Veritas-bu] Moving to new master Hi All, we are planing to move our netbackup master server to newely built Windows 2003 box old master windows - 2000 veritas version : 5.0MP3 last time we tried this and when trying to configure storage devices none of the tape drives were detected for master (all the drives are visible from OS level)and it throwed an error, "could not get device configaration, cannot configure devices, see troubleshoting guide for details (44) " "device discovery failed on host <Master-server>" tpautoconf -a gives "Fatal Global Database consistancy error" any idea what is going wrong here any tech note that i can refer in this situation ? +---------------------------------------------------------------------- |This was sent by [EMAIL PROTECTED] via Backup Central. |Forward SPAM to [EMAIL PROTECTED] +---------------------------------------------------------------------- _______________________________________________ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu This email (including any attachments) may contain confidential and/or privileged information or information otherwise protected from disclosure. If you are not the intended recipient, please notify the sender immediately, do not copy this message or any attachments and do not use it for any purpose or disclose its content to any person, but delete this message and any attachments from your system. Astrium disclaims any and all liability if this email transmission was virus corrupted, altered or falsified. --------------------------------------------------------------------- Astrium Limited, Registered in England and Wales No. 2449259 REGISTERED OFFICE:- Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England _______________________________________________ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu _______________________________________________ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu