Yup. Did all that. ☺ Dennis Peacock Data Protection and Recovery Engineer [acxiom]
Acxiom Corporation From: [email protected] [mailto:[email protected]] On Behalf Of Rusty Major Sent: Thursday, August 15, 2013 4:47 PM To: [email protected] Subject: Re: [Veritas-bu] Converting standard client to a media server Hey Dennis, Did you change the IP or hostname? clear host cache (bpclntcmd -clear_host_cache) on all boxes? Restart PBX on master? Can you run nbemmcmd -listhosts from the new media server? Did you manually add the new media server to the master: ./nbemmcmd -addhost -machinename <newmedianame> -machinetype -media -masterserver <mastername> -operatingsystem <os type> -netbackupversion <version> I think that's what the command is. I'm sure you've done all that, but thought I would throw it out there. On Thu, Aug 15, 2013 at 4:25 PM, Dennis Peacock <[email protected]<mailto:[email protected]>> wrote: Netbackup 7.5.0.5 Both boxes are RedHat Linux Release 6 Box "A" is the master and has always been the master/media server. Box "B" has always been a standard client backing up across the network. Licensing purchased and Box "B" was cleanly installed as a media server. The master server can't see Box "B" as a media server. bp.conf file checked and tweaked on both boxes. Netbackup has been stopped and restarted several times. Tried to manually add it to the master and I get this message: globalDB hostname has not been set (Status 4) 4 of us have tried to get this working.....all have failed so far. Tips, pointers, tricks, advice......all would be appreciated. +---------------------------------------------------------------------- |This was sent by [email protected]<mailto:[email protected]> via Backup Central. |Forward SPAM to [email protected]<mailto:[email protected]>. +---------------------------------------------------------------------- _______________________________________________ Veritas-bu maillist - [email protected]<mailto:[email protected]> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu -- Rusty Major ▪ Technical Architect and Team Lead - Backup Infrastructure Engineering ▪ Sungard Availability Services ▪ 757 N. Eldridge Pkwy., Suite 200, Houston, TX 77079 ▪ 281-584-4693 ▪ Cell 713-724-4914 ▪ [email protected]<mailto:[email protected]> ------------------------------------------------------------------------------ Think before you Print CONFIDENTIALITY: This e-mail (including any attachments) may contain confidential, proprietary and privileged information, and unauthorized disclosure or use is prohibited. If you received this e-mail in error, please notify the sender and delete this e-mail from your system. *************************************************************************** The information contained in this communication is confidential, is intended only for the use of the recipient named above, and may be legally privileged. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please resend this communication to the sender and delete the original message or any copy of it from your computer system. Thank You. ****************************************************************************
<<inline: image001.jpg>>
_______________________________________________ Veritas-bu maillist - [email protected] http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
