You had 2 failures. No real way to design around that. GAB "visible" would prevent bad things from occurring.
-----Original Message----- From: veritas-ha-boun...@mailman.eng.auburn.edu [mailto:veritas-ha-boun...@mailman.eng.auburn.edu] On Behalf Of Imri Zvik Sent: Sunday, May 03, 2009 11:20 AM To: veritas-ha@mailman.eng.auburn.edu Subject: [Veritas-ha] LLT heartbeat redundancy Hi, As far as I understand the manuals, the LLT heartbeat links should be isolated from each other. Now, consider the following scenario - Node1 is connected with two links, each one to a sperate switch. We will call them li...@node1@sw1 and li...@node1@sw2. Node4 is also connected with 2 links: li...@node4@sw1 and li...@node4@sw2. Now, if Node1 lose li...@node1@sw1 and Node4 lose li...@node4@sw2, they can no longer see each other, although they still have a valid heartbeat link. Am I missing something? Is there a way around this issue? -- imriz _______________________________________________ Veritas-ha maillist - Veritas-ha@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-ha _______________________________________________ Veritas-ha maillist - Veritas-ha@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-ha