Maybe you would like to consider one of those cables: https://www.wekomm.de/de/messtechnik-komponenten-der-wekomm-engineering-gmbh.html They are available in four and two wire and feature a very high quality low thermal spade connector. Regards Hubert
-----Ursprüngliche Nachricht----- Von: [email protected] [mailto:[email protected]] Gesendet: Donnerstag, 7. September 2023 09:30 An: [email protected] Betreff: volt-nuts Digest, Vol 146, Issue 1 Send volt-nuts mailing list submissions to [email protected] To subscribe or unsubscribe via email, send a message with subject or body 'help' to [email protected] You can reach the person managing the list at [email protected] When replying, please edit your Subject line so it is more specific than "Re: Contents of volt-nuts digest..." Today's Topics: 1. Datron Special Lead Kit ([email protected]) 2. Re: Datron Special Lead Kit (Massimo Ortolano) ---------------------------------------------------------------------- Message: 1 Date: Wed, 6 Sep 2023 13:11:01 +0000 From: [email protected] Subject: [volt-nuts] Datron Special Lead Kit To: [email protected] Message-ID: <[email protected]> Content-Type: text/plain; charset=UTF-8 Hello Group, in the datron manuals of voltmeters and calibrators is mentioned a special lead kit.\ Does somebody know what it is and how it looks like? \ Searching internet i can not find anything.\ \ Thank you\ Jürgen ------------------------------ Message: 2 Date: Wed, 6 Sep 2023 14:38:53 +0000 From: "Massimo Ortolano" <[email protected]> Subject: [volt-nuts] Re: Datron Special Lead Kit To: Discussion of precise voltage measurement <[email protected]> Message-ID: <[email protected]> Content-Type: multipart/signed; boundary="Apple-Mail=_DF1A92C2-312D-46BE-BA4D-E515F17E58CE"; protocol="application/pkcs7-signature"; micalg=sha-256 Hi, It likely refers to the low thermal voltage leads with spade connectors and guard, like these: https://www.calplus.de/fluke-8588a-lead-thermal.html The red and black wires form a twisted pair and the blue wire is the shield, which should be connected to the guard terminal of the voltmeter. You need two of them in the case of four-wire resistance measurements. Best, Massimo -- Massimo Ortolano Dipartimento di Elettronica e Telecomunicazioni Politecnico di Torino Office: +39 011 090 4121 Mobile: +39 391 157 9193 > On 6 Sep 2023, at 15:11, [email protected] wrote: > > Hello Group, > > in the datron manuals of voltmeters and calibrators is mentioned a special > lead kit.\ > Does somebody know what it is and how it looks like? \ > Searching internet i can not find anything.\ > \ > Thank you\ > Jürgen > _______________________________________________ > volt-nuts mailing list -- [email protected] -- To unsubscribe send an > email to [email protected] > To unsubscribe, go to and follow the instructions there. -------------- next part -------------- A message part incompatible with plain text digests has been removed ... Name: smime.p7s Type: application/pkcs7-signature Size: 2389 bytes Desc: not available ------------------------------ Subject: Digest Footer _______________________________________________ volt-nuts mailing list -- [email protected] To unsubscribe send an email to [email protected] %(web_page_url)slistinfo%(cgiext)s/%(_internal_name)s ------------------------------ End of volt-nuts Digest, Vol 146, Issue 1 ***************************************** _______________________________________________ volt-nuts mailing list -- [email protected] -- To unsubscribe send an email to [email protected] To unsubscribe, go to and follow the instructions there.