* This is the VOP Radius mailing list * No, I have removed the port limit on this user. Also, if it were a port limit issue, it would show up in the error log as "Simultaneous login limit exceeded". I'm not getting anything in the error log. But I do see in the accounting log the disconnect cause which I mentioned earlier.
-----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Larry Essary Sent: Thursday, December 05, 2002 11:28 AM To: [EMAIL PROTECTED] Subject: [VOP RADIUS] Max 4048 and MPP At 10:57 AM 12/5/02, you wrote: * This is the VOP Radius mailing list * look in your radius profile and see what value you have for "port-limit". It is probably only 2 . Larry At one of our POPs we have 3 Max 4048s on which we've enabled Stacking (Ethernet -> Mod Config -> Stack Options) so ISDN users can establish MPP connections regardless of which Max they connect to (all 3 use trunks that are in the same hunt group). This works fine for users establishing a MPP call with 2 B-channels, but we have a user that is wanting to use 2 ISDN lines and bond all 4 channels. The first 2 work fine, but when the third one dials up, it disconnects with cause code 49, "Disconnected MP call because no more channels can be added." According to Lucent's documentation, the Max 4048 supports up to 40 stacked channels. Does anyone know why this third channel is being rejected? The customer is using a Cisco router if it makes any difference. Scott Collins, CCNA Senior Network Administrator The MultiPro Network [EMAIL PROTECTED] ** To leave this list, send an email to [EMAIL PROTECTED] and put the word "LEAVE" in the BODY of the email. ** To leave this list, send an email to [EMAIL PROTECTED] and put the word "LEAVE" in the BODY of the email.