After adding mplsTunnelAddDel.mtSwIfIndex = 0;
still the same time out. Jozef Glončák Pantheon Technologies, s. r. o. ________________________________ From: Neale Ranns (nranns) <[email protected]> Sent: Friday, September 29, 2017 20:45 To: Jozef Glončák; [email protected] Subject: Re: mpls tunnel configuration through JVPP Hi Jozef, To what did you set: mt_sw_if_index ? It should be ~0 on the creation of a new tunnel. /neale -----Original Message----- From: Jozef Glončák <[email protected]> Date: Friday, 29 September 2017 at 04:09 To: "[email protected]" <[email protected]> Cc: "Neale Ranns (nranns)" <[email protected]> Subject: mpls tunnel configuration through JVPP Hello Neale, I need to do following configuration (VPP CLI) >>>mpls tunnel add via 10.10.1.3 GigabitEthernet0/a/0 out-label 1003 through JVPP. I tried method >>>FutureJVppCore.mplsTunnelAddDel() with settings [1] but result was that request time outed with no error [1] mplsTunnelAddDel.mtIsAdd = 1; mplsTunnelAddDel.mtNextHop = new byte[] {10,10,1,3}; mplsTunnelAddDel.mtNextHopNOutLabels = 1; mplsTunnelAddDel.mtNextHopOutLabelStack = new int[] {1003}; mplsTunnelAddDel.mtNextHopProtoIsIp4 = 1; mplsTunnelAddDel.mtNextHopSwIfIndex = 2; // index of GigabitEthernet0/a/0 Jozef Glončák Pantheon Technologies, s. r. o.
_______________________________________________ vpp-dev mailing list [email protected] https://lists.fd.io/mailman/listinfo/vpp-dev