Hi Sam,

Would you be willing to create unittests for the scenarios you are testing?

On Wed, Mar 13, 2019 at 1:00 PM Ole Troan <otr...@employees.org> wrote:

> > I am setting MTU to 1500 and trying to test larger packets. (by enabling
> reassembly feature on interfaces)
> > It seems to work fine on regular interfaces. and On tunnel interfaces
> packets are getting struck in reassembly saying inconsistent UDP/IP lengths.
> > So thought of checking with the community.
>
> OK, please share your exact setup and we can take a look.
>
> Cheers,
> Ole-=-=-=-=-=-=-=-=-=-=-=-
> Links: You receive all messages sent to this group.
>
> View/Reply Online (#12514): https://lists.fd.io/g/vpp-dev/message/12514
> Mute This Topic: https://lists.fd.io/mt/30410981/1594641
> Mute #vnet: https://lists.fd.io/mk?hashtag=vnet&subid=3512467
> Group Owner: vpp-dev+ow...@lists.fd.io
> Unsubscribe: https://lists.fd.io/g/vpp-dev/unsub  [
> pvi...@vinciconsulting.com]
> -=-=-=-=-=-=-=-=-=-=-=-
>
-=-=-=-=-=-=-=-=-=-=-=-
Links: You receive all messages sent to this group.

View/Reply Online (#12515): https://lists.fd.io/g/vpp-dev/message/12515
Mute This Topic: https://lists.fd.io/mt/30410981/21656
Mute #vnet: https://lists.fd.io/mk?hashtag=vnet&subid=1480452
Group Owner: vpp-dev+ow...@lists.fd.io
Unsubscribe: https://lists.fd.io/g/vpp-dev/unsub  [arch...@mail-archive.com]
-=-=-=-=-=-=-=-=-=-=-=-