Hi all,

Ben's fix for the worker clock drift, 46956 "vppinfra: keep time monotonic 
while tracking wall clock", was merged to master today (7d65ef4b8), and 46994 
picks it up for stable/2610.

I'd like to ask for it on stable/2606 as well. On 26.06 the worker clocks drift 
away from main (we measured about 1.7 ms/min), and on our production routers 
that made LACP stop transmitting on bonded links. Background is in the thread 
"26.06: worker thread clocks drift ahead of main, LACP stops transmitting".

The change applied cleanly to our 26.06 base, and we ran it on a 26.06 lab 
router for 21 h with no drift (results are on the change). I'm happy to push 
the stable/2606 cherry-pick myself if that's the preferred way.

Regards,
Pieter
-=-=-=-=-=-=-=-=-=-=-=-