Hello all, I hope everyone has been doing well. I have a question concerning vserver ctx-17c.
I have implemented vservers (2.4.20-ctx17) with multiple IP addresses located on separate physical networks and several of our admins have reported that traffic is not always moving out across the appropriate adapters. From various posts to the vserver mailing list, I saw that ctx-17a through ctx-17c fixed various networking "anomalies" :-) Because of driver issues, I need to stay at kernel 2.4.20, however I have seen that ctx-17c is only available for 2.4.21 and 2.4.22. Here is what I did: I took a virgin 2.4.21 tarball and exploded it into two separate trees. One tree was patched with ctx-17, while the other was patched with ctx-17c. I then create a patch from the diff of these two trees. Then on a 2.4.20 tree that had been patched with ctx-17, I applied my new ctx-17 to ctx-17c diff. I saw two hunks fail...one I was able to correct by hand (socket.c IIRC), the other I was unable to fix...it was a hunk in udp.c (IIRC) that had to do with ipv6, so I went on and ignored it because I do not use ipv6. My kernel compiled correctly, I upgraded to vserver-23 tools and upon rebooting, my system is up and running with 4 vservers. My question is this: Is what I did OK? Are the fixes that went into moving from ctx-17c specific to major changes to the kernel while moving from 2.4.20 to 2.4.21 and 2.4.22? Or are the ctx-17 to ctx-17c changes applicable to 2.4.20 as well? Thank you. Mike