ppp

 

You are right. This is a new router with a new ISP and we have not
gotten the link up with the LEC for testing yet.  Thanks for the
feedback.

 

-Chad

 

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Aubrey
Wells
Sent: Wednesday, March 05, 2008 10:09 AM
To: [EMAIL PROTECTED]
Subject: Re: [Vyatta-users] vif 1 on wan0

 

Is your serial connection up? You won't be able to ping it until the
connection comes up because that's when the vif gets created. if you do
a ifconfig from the shell, you will probably see that wan0.1 is not
created yet.

 

Are you using ppp or c-hdlc?


------------------

Aubrey Wells

Senior Engineer

Shelton | Johns Technology Group

A Vyatta Ready Partner

www.sheltonjohns.com

 

 





 

On Mar 5, 2008, at 10:06 AM, Chad Hurley wrote:





Sorry for all the questions but this is the first time I have used
anything outside of Ethernet on a Vyatta router.

 

I have configured a Sangoma A301 card and the system finds fine.

 

I have configured it with vif 1 and assigned an address.  However, when
I try to ping the address from the router itself I get the error:

 

connect: Network is unreachable

 

Am I missing something?

 