Hi, it’s me again!

Rich, may be a last quick step to try, before writing a test program.

What you can do is the following:

Take the list of RFM69 frequencies in your spread sheet.
Sort them from low to high.
Subtract from each of the 51 frequencies the value 26062 (Hz)
Use these smaller (and sorted) frequencies in protogol.go

Explanation: the frequencies of the original rtldavis program and the sorted 
RFM69 frequencies all differ about 26000 Hz from each other.

The sorted hop frequencies differ about 51000 Hz from their ‘neighbour’ 
frequency, so an offset of 26000 Hz from the good frequency is too much as we 
have seen.

Test have already shown that the first frequency of rtldavis is good: we 
received the data of both transmitters. The first RFM69 frequency differs 26062 
Hz with the first rtldavis frequency.

Let me know if you like the idea or have any questions.

Cheers, Luc

Reply via email to