I think you're going to have to ask a clearer question with some data 
showing what you think you're seeing.

Quick read of rtl-davis seems to say that if you set debug=2 you'll see 
debug logs with the string "temp_raw" in it that might help.  Look around 
line 1180 
of https://github.com/lheijst/weewx-rtldavis/blob/master/bin/user/rtldavis.py 
for the actual code there.

On Saturday, January 11, 2025 at 1:00:40 PM UTC-8 Jesper Johansen wrote:

> I have installed newest version of RTLdavis (latest release 27-04-2020) 
> together with weewx ver 5.1.0. I am chasing a difference at around 0.5 deg 
> C between observation from RTLDavis driver and weewx/Vantage pro 2 driver. 
> Weewx use target_unit = US so the temperature in the database is in 
> Fahrenheit. Temperatures reveived in RTLDavis is in Fahrenheit but RTLDavis 
> convert it to Celsius and then before it is saved in the DB again converted 
> to Fahrenheit.
> What is the background for converting to Celsius in RTLDavis?
> Thanks Jesper
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-development" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion visit 
https://groups.google.com/d/msgid/weewx-development/407efec3-56cc-4eaa-8176-8404dee10284n%40googlegroups.com.

Reply via email to