Hi Christopher,

1475731610 looks ok but what of the record after it? In particular the 
usUnits field.

Gary

On Friday, 21 October 2016 16:54:50 UTC+10, Christopher McAvaney wrote:
>
> G'day,
>
> Was following the instructions to clean up a bad rain reading from 
> https://github.com/weewx/weewx/wiki/Cleaning-up-old-'bad'-data
>
> But, when I execute the --backfill-daily option I am getting a "Unit 
> system mismatch" error.
>
> $ wee_database --drop-daily
> Using configuration file /etc/weewx/weewx.conf
> Using database binding 'wx_binding', which is bound to database 
> 'archive_mysql'
> Proceeding will delete all your daily summaries from database 'weewx'
> Are you sure you want to proceed (y/n)? y
> Dropping daily summary tables from 'weewx' ...
> Dropped daily summary tables from database 'weewx'
>
> $ wee_database --backfill-daily --dry-run
> Using configuration file /etc/weewx/weewx.conf
> Using database binding 'wx_binding', which is bound to database 
> 'archive_mysql'
> Backfilling daily summaries in database 'weewx' ...
> Traceback (most recent call last):te: 2016-10-06 16:26:50 AEDT (1475731610)
>   File "/usr/bin/wee_database", line 444, in <module>
>     main()
>   File "/usr/bin/wee_database", line 153, in main
>     backfillDaily(config_dict, db_binding, int(options.trans_days))
>   File "/usr/bin/wee_database", line 217, in backfillDaily
>     nrecs, ndays = dbmanager.backfill_day_summary(trans_days=trans_days)
>   File "/usr/share/weewx/weewx/manager.py", line 1374, in 
> backfill_day_summary
>     _day_accum.addRecord(_rec)
>   File "/usr/share/weewx/weewx/accum.py", line 240, in addRecord
>     func(self, record, obs_type, add_hilo)
>   File "/usr/share/weewx/weewx/accum.py", line 335, in check_units
>     self._check_units(record['usUnits'])
>   File "/usr/share/weewx/weewx/accum.py", line 348, in _check_units
>     raise ValueError("Unit system mismatch %d v. %d" % (self.unit_system, 
> new_unit_system))
> ValueError: Unit system mismatch 1 v. 0
>
>
> In looking at the data for that timestamp, everything looks o.k.:
> "dateTime" "usUnits" "interval" "barometer" "pressure" "altimeter" 
> "inTemp" "outTemp" "inHumidity" "outHumidity" "windSpeed" "windDir" 
> "windGust" "windGustDir" "rainRate" "rain" "dewpoint" "windchill" 
> "heatindex" "ET" "radiation" "UV" "extraTemp1" "extraTemp2" "extraTemp3" 
> "soilTemp1" "soilTemp2" "soilTemp3" "soilTemp4" "leafTemp1" "leafTemp2" 
> "extraHumid1" "extraHumid2" "soilMoist1" "soilMoist2" "soilMoist3" 
> "soilMoist4" "leafWet1" "leafWet2" "rxCheckPercent" "txBatteryStatus" 
> "consBatteryVoltage" "hail" "hailRate" "heatingTemp" "heatingVoltage" 
> "supplyVoltage" "referenceVoltage" "windBatteryStatus" "rainBatteryStatus" 
> "outTempBatteryStatus" "inTempBatteryStatus"
> "1475731610" "1" "5" "29.43787700257" "29.3473124630833" "29.432883539847" 
> "82.4" "79.34" "45" "36" "9.17143879392" "315" "12.07945597248" "315" "0" 
> "0" "50.0428531173988" "79.34" "79.34" \N \N \N \N \N \N \N \N \N \N \N \N 
> \N \N \N \N \N \N \N \N "100" \N \N \N \N \N \N \N \N \N \N "0" \N
>
> I don't really understand why this error is thrown as the backfill works 
> for 10's of thousands of records until that particular date.
>
> Does anybody know why it would be throwing this unit error?
>
> Thanks in advance,
> Christopher
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to weewx-user+unsubscr...@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to