Yes, windchill is correct on the station. Says -30F right now. I'm going to try switching it to software to see if it fixes it for now.
I have a feeling that the driver isn't grabbing it correctly. -Mark On Tuesday, December 26, 2017 at 3:54:03 AM UTC-6, gjr80 wrote: > > Hmm, accoding to the Hardware Guide ( > http://weewx.com/docs/hardware.htm#wmr200_notes) the WMR200 calculates > and provides windchill to weeWX. So it's likely either the WMR200 driver is > decoding windchill incorrectly or the station is outputting nonsense > windchill now and then. Does windchill always display correctly on the > station? Probably need a WMR200 expert I suspect. > > You could force weeWX to calculate windchill by setting windchill=software > under StdWXCalculate in weewx.conf but this will only give you a windchill > value when you have non-None values for outTemp AND windSpeed in the > packet/record. Arguably this is only masking the issue rather than fixing > it. > > Gary > > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. For more options, visit https://groups.google.com/d/optout.