Is your smarthub directly connected to the RPI?

On Saturday, October 27, 2018 at 7:06:14 PM UTC-4, Gabe wrote:
>
> Thanks! Works! Except Belchersking giving me  
>
> Generate failed with exception '<type 'exceptions.ValueError'>'
>
> but that's not related to acurite :)
>
> On Saturday, October 27, 2018 at 7:04:16 PM UTC-4, rich T wrote:
>>
>> Here is my mapping:
>>
>> [[sensor_map]]
>>         
>>         # bridge
>>         
>>         barometer = pressure.00001532.*
>>         
>>         # tower
>>         
>>         outTemp = temperature.00001532.*
>>         outHumidity = humidity.00001532.*
>>         windSpeed = windspeed.00001532.*
>>         windDir = winddir.00001532.*
>>         rain = rainfall.00001532.*
>>
>>         # Indoor Sensor (Backroom)
>>
>>         inTemp = temperature.00008397.*
>>         inHumidity = humidity.00008397.* 
>>
>>
>>
>> On Saturday, October 27, 2018 at 3:32:24 PM UTC-4, Gabe wrote:
>>>
>>> More specifically, I have no idea how to setup the sensor_map section of 
>>> weewx.conf, I don't know how to get the inTemp = temperature.06022.* 
>>> sensor ids
>>>
>>> On Thursday, October 18, 2018 at 7:47:13 PM UTC-4, rich T wrote:
>>>>
>>>> Here is my configuration:
>>>>
>>>> Smarthub >(Port 1)  Managed Switch (Port 2) > RP3
>>>>
>>>> Port 2 is mirror of Port 1.  And used the weewx-interceptor driver to 
>>>> process the data.
>>>>
>>>> On Wednesday, October 17, 2018 at 10:39:49 AM UTC-4, Gabe wrote:
>>>>
>>>>> Trying to see if I can get the smarthub connected directly into the Pi 
>>>>> since I can't redirect DNS with Google Wifi (not enough advanced settings)
>>>>>
>>>>>
>>>>>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.

Reply via email to