@Gary fyi:
I updated my GW1100 to the newly released firmware 2.0.4 and it now produces the following error (including refusing to archive data)
Looks like the internal sensor map has been enlarged.
FW 2.0.3 still ran without such problems.

Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] INFO user.gw1000: driver version is 0.3.1 Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] INFO user.gw1000: GW1000 address is 192.168.1.53:45000 Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] INFO user.gw1000: poll interval is 10 seconds Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] INFO weewx.engine: StdConvert target unit is 0x1 Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****  Traceback (most recent call last): Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****    File "/usr/share/weewx/user/gw1000.py", line 2827, in run Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****      self.client.collect_sensor_data() Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****    File "/usr/share/weewx/user/gw1000.py", line 2282, in collect_sensor_data Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****      queue_data = self.get_live_sensor_data() Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****    File "/usr/share/weewx/user/gw1000.py", line 2329, in get_live_sensor_data Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****      self.update_sensor_id_data() Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****    File "/usr/share/weewx/user/gw1000.py", line 2344, in update_sensor_id_data Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     **** self.sensors_obj.set_sensor_id_data(sensor_id_data) Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****    File "/usr/share/weewx/user/gw1000.py", line 4108, in set_sensor_id_data Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****      batt_fn = Gw1000Collector.sensor_ids[data[index:index + 1]]['batt_fn'] Sep 26 01:08:07 raspberrypi weewx-GW1000[24829] CRITICAL user.gw1000:     ****  KeyError: b'0'

I switched to an older GW1000 1.6.8 not to lose data.

best regards

Rainer

--
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to weewx-user+unsubscr...@googlegroups.com.
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/a2f8e670-ed20-be0a-be33-52528a8cd1ac%40gmail.com.

Reply via email to