It is not working with StdCalibrate [StdCalibrate] [[Corrections]] # For each type, an arbitrary calibration expression can be given. # It should be in the units defined in the StdConvert section. # Example: foo = foo + 0.2 outHumidity = extraHumid1
I am getting correct values in extraHumid1 from replacement sensor. I checked database. But outHumidity is stil getting value from dead station sensor. sreda, 8. november 2023 ob 11:14:14 UTC+1 je oseba tadej.j...@gmail.com napisala: > I will try this one for now! I hope weewx will use it later to calculate > dew point and heat index with this value. > > [StdCalibrate] > [[Corrections]] > outHumidity = extraHumid1 if extraHumid1 is not None else None > > torek, 7. november 2023 ob 12:36:26 UTC+1 je oseba michael.k...@gmx.at > napisala: > >> Thanks, I forgot about that! Then I would definitely prefer getting an >> Ecowitt Gateway + outdoor sensor over the replacement part. >> >> gjr80 schrieb am Montag, 6. November 2023 um 21:08:54 UTC+1: >> >>> Not necessary, if the Ecowitt gateway driver can be used it can be run >>> as a data service to augment an existing driver. >>> >>> Gary >>> >>> On Tuesday, 7 November 2023 at 06:03:39 UTC+10 michael.k...@gmx.at >>> wrote: >>> >>>> With the ecowitt gateway you need a second weewxd running, as a >>>> downside. But you can build a whole new station, step by step, around that >>>> gateway (which is probably way to go, sooner or later). >>>> >>>> vince schrieb am Montag, 6. November 2023 um 20:41:08 UTC+1: >>>> >>>>> Another option is an ecowitt gateway and their outside T+H sensor, >>>>> which integrates well into weewx. >>>>> >>>>> On Monday, November 6, 2023 at 11:19:23 AM UTC-8 michael.k...@gmx.at >>>>> wrote: >>>>> >>>>>> Do not use a BME280 as an outdoor Sensor, it is not suited for this >>>>>> purpose. The operating range is only valid in non-condensing >>>>>> environments. >>>>>> In condensing environments, especially below freezing point, these >>>>>> sensors >>>>>> are proven unusable. Go for a SHT3x or SHT4x. >>>>>> >>>>>> Mark Fraser schrieb am Montag, 6. November 2023 um 18:32:59 UTC+1: >>>>>> >>>>>>> On 06/11/2023 08:18, tadej.j...@gmail.com wrote: >>>>>>> > Hello i have ws2300 station and my humidity sensor probably died. >>>>>>> It >>>>>>> > only shows values from 70 to 80% .I cannot get replacement part >>>>>>> anywhere >>>>>>> > because it is not in production anymore and I cannot buy whole new >>>>>>> > station because it will be complicated to get all things up >>>>>>> running again. >>>>>>> > >>>>>>> > I was thinking of getting external humidity sensor and hook it to >>>>>>> > arduino board and then read humidity values remotely via crontabs >>>>>>> in a >>>>>>> > txt file. Is is somehow possible to "trick" weewx to read this >>>>>>> value >>>>>>> > instead of getting it from station because I am using weewx to >>>>>>> calculate >>>>>>> > heat index and dew point. >>>>>>> Could you use something like BME280WX from here? >>>>>>> https://gitlab.com/wjcarpenter/bme280wx >>>>>>> >>>>>> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/0d8984ab-6bb1-4380-8b05-3dc74b41134en%40googlegroups.com.