Yes, that was it. Thank you grj80, I was also able to assign the signal quality of other unknown devices.
Have a nice day and stay healthy. gjr80 schrieb am Dienstag, 27. Februar 2024 um 20:29:12 UTC: > The problem is WeeWX does not know whether your sensor battery fields are > temperatures, pressures or voltages etc so WeeWX presents the data as it > comes out of the database and with no units labels. To have WeeWX take care > of formatting and unit labels each field needs to be assigned to a WeeWX > unit group, the Ecowitt gateway driver does this automatically for all > WeeWX fields in the default file map, but if you decide to change the field > mapping you are responsible for making the unit group assignments yourself. > There are a number of ways you can do this, but the easiest is to add a few > lines of code to bin/user/extensions.py (the location of > bin/user/extensions.py is dependent on how you installed WeeWX, refer to > Location > of WeeWX components > <http://weewx.com/docs/5.0/usersguide/where/#location-of-weewx-components> > in the User's Guide). Try adding the following to extensions.py: > > import weewx.units > weewx.units.obs_group_dict['soilMoistBattx'] = 'group_volt' > > add a weewx.units.obs_group_dict entry for each field you have added. > Once you have made the changes save extensions.py and restart WeeWX. > WeeWX will then apply the default group_voltage formatting and unit > labelling for your sensor battery fields. > > Gary > On Wednesday 28 February 2024 at 03:20:55 UTC+10 mike.g...@gmail.com > wrote: > >> Hello. >> >> I have a clean Debian 12 and WeeWX 5.0.2 installation and am currently >> configuring the ecowitt devices (GW1100, WH65, WH51, WH31, WN34, WH55 and >> WH57). >> >> I am using the Ecowitt Gateway v0.6.1 from gjr80 as the driver. >> >> The voltages of soilTemp and soilMoist should be displayed under " >> Sensors". >> The missing columns "soilMoistBattx" and "soilTempBattx" have been added >> to the SQL database. >> >> Now the voltages on the left are displayed with 6 digits after the >> decimal point. >> The driver and the graphics on the right correctly show 2 digits after >> the decimal point. >> >> Whats wrong? How can I fix this? >> >> Greetings, Mike >> >> [image: Screenshot 2024-02-22 at 12-36-32 Test City.png] >> > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/b1792035-c261-407f-859c-be707d5b0c6an%40googlegroups.com.