Dear Wien2k users
I am PhD student
I work on wien2k and BoltzTraP codes
My problem is how to extract the value of the seebeck coefficient versus the 
Temperature
My input is :
WIEN0 0 0 0.00.814 0.0005 0.1 712CALC3BOLTZ0.151000. 50.-1HISTO
In the file case.trace, i obtain different value of fermi energy at different 
Temperatures and at different carrier concentrations
Thus, which seebeck coefficient i choose ? (the carrier concentartion varies at 
the same time with the fermi enegy and the temperature)
With my best regards
Ali ALLAMAix Marseille universityPhD - Physics of materialsMarseille 13013 - 
FRANCE                                                                          
     
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20121029/38e667f7/attachment-0001.htm>

Reply via email to