The default value 0.30 has to be changed. Use the –in1ef switch in
runsp_lapw

This is NOT TRUE ! When you use the latest WIEN2k version, I do NOT recommend -in1ef anymore. Any 0.30 will be automatically adjusted to EF-0.2 Ry.



*From:*[email protected]
[mailto:[email protected]] *On Behalf Of *Peram
sreenivasa reddy
*Sent:* Tuesday, May 28, 2013 5:46 PM
*To:* A Mailing list for WIEN2k users
*Subject:* Re: [Wien] Problem in SO calculation

Dear Ghosh,

These are my case.in1 and case.inso files

case.in1:

WFFIL  EF=.01061   (WFFIL, WFPRI, ENFIL, SUPWF)
   9.00       10    4 (R-MT*K-MAX; MAX L IN WF, V-NMT
   0.30    5  0      (GLOBAL E-PARAMETER WITH n OTHER CHOICES, global
APW/LAPW)
  0    0.30      0.000 CONT 1
  0   -3.72      0.001 STOP 1
  1   -2.07      0.002 CONT 1
  1    0.30      0.000 CONT 1
  2    0.30      0.005 CONT 1
   0.30    5  0      (GLOBAL E-PARAMETER WITH n OTHER CHOICES, global
APW/LAPW)
  0    0.30      0.000 CONT 1
  0   -4.35      0.001 STOP 1
  1   -2.58      0.002 CONT 1
  1    0.30      0.000 CONT 1
  2    0.30      0.005 CONT 1
   0.30    3  0      (GLOBAL E-PARAMETER WITH n OTHER CHOICES, global
APW/LAPW)
  1    0.30      0.000 CONT 1
  1   -4.80      0.001 STOP 1
  0    0.30      0.000 CONT 1
K-VECTORS FROM UNIT:4   -9.0 5.0    95   emin/emax/nband

case.inso:

WFFIL
4  0 0 llmax,ipr,kpot
-10 1.5 Emin, Emax
     0 0 1 h,k,l (direction of magnetization)
  3 number of atoms with RLO
1 -2.07 0.002 CONT atom-number, E-param for RLO
2 -2.58 0.002 CONT atom-number, E-param for RLO
3 -4.80 0.001 STOP atom-number, E-param for RLO
0 0 number of atoms without SO, atomnumbers




On Tue, May 28, 2013 at 5:40 PM, Ghosh SUDDHASATTWA
<[email protected] <mailto:[email protected]>> wrote:

Please attach your case.in1(c) and case.inso files

Suddhasattwa

*From:*[email protected]
<mailto:[email protected]>
[mailto:[email protected]
<mailto:[email protected]>] *On Behalf Of *Peram
sreenivasa reddy
*Sent:* Tuesday, May 28, 2013 5:33 PM
*To:* A Mailing list for WIEN2k users
*Subject:* Re: [Wien] Problem in SO calculation

Dear Ghosh and Stefaan,

Thank you very much for your replay. I completed SO for non magnetic
case. Now i want to run SO in magnetic case. This error came while
running in Magnetic case.

Dear Ghosh sir, I tried your commands. Still same error is coming.

On Tue, May 28, 2013 at 5:19 PM, Stefaan Cottenier
<[email protected] <mailto:[email protected]>> wrote:


See the FAQ: http://www.wien2k.at/reg_user/faq/qtlb.html

Stefaan

                I got error like below while running SO calculation.
Can i  know how to rectify it.

   LAPW0 END
   LAPW1 END
   LAPW1 END
LAPWSO END
L2main - QTL-B Error

_______________________________________________
Wien mailing list
[email protected] <mailto:[email protected]>
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:
http://www.mail-archive.com/[email protected]/index.html



_______________________________________________
Wien mailing list
[email protected] <mailto:[email protected]>
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:
http://www.mail-archive.com/[email protected]/index.html





_______________________________________________
Wien mailing list
[email protected]
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/[email protected]/index.html


--

                                      P.Blaha
--------------------------------------------------------------------------
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300             FAX: +43-1-58801-165982
Email: [email protected] WWW: http://info.tuwien.ac.at/theochem/
--------------------------------------------------------------------------
_______________________________________________
Wien mailing list
[email protected]
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/[email protected]/index.html

Reply via email to