Dear Dr. Tran and WIEN2k community,

I have a question related to this topic.

DOS plot with the "-hf" switch is truncated at a lower energy than Emax value 
in the case.int file.
The Emax in "-hf" mode is determined by the "nband" variable in case.inhf file?

Could you please tell me the detailed definition of the DOS plot generation 
with full hybrid functional calculation?

Thank you in advance

Shinichi Nishimura


On 2013/09/19, at 1:13, t...@theochem.tuwien.ac.at wrote:

> Hi,
> 
> For DOS calculation with full hybrid functionals you need to
> execute lapw2 and tetra with -hf:
> x lapw2 -qtl -hf (-up/dn)
> x tetra -hf (-up/dn)
> 
> Maybe this was the problem. This is not explained in the users's guide,
> but we will add a paragraph about that soon.
> 
> F. Tran
> 
> On Wed, 18 Sep 2013, abdel Mar.. wrote:
> 
>> dear Wien2k community,
>> i'm interested on the calculation of gap for 4f materials with hybrid 
>> functional.
>> (1) with onsite B3PW91
>>  (2) with full hybrid  B3PW91
>> for (1)  the value with grep GAP  case.scf  in agreement with  difference 
>> betwwen (the top) VB 
>> and (the bottom) of CB in Total DOS plot, also in agrement with expt. value 
>> ~ 3eV
>> for (2) i have 2 values
>>  big one with grep GAP in the scf file   ~ 3.4 eV
>> small from total DOS plot ~ 0.8 eV
>> can any one tell me please where this difference comes from for the same 
>> full hybrid functional
>> and between on site and full hybrid functional?
>> Regards
>>  
>> M.
> _______________________________________________
> Wien mailing list
> Wien@zeus.theochem.tuwien.ac.at
> http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
> SEARCH the MAILING-LIST at:  
> http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html