On 05/09/2014 10:27 PM, Kefeng Wang wrote:
Dear All,

I tried to follow the SrVO3 example in wien2wannier 1.0 beta2 and
Wannier90 1.2. Everything went well until the command ‘x wplot –wf –m”
failed. The error message  is “forrtl: severe (59): list-directed I/O
syntax error, unit -5, file Internal List-Directed Read”. Before that, I
compared the bandstructures and it is good. Could anybody help me out?

Sorry, I see I was a bit too fast there -- it is an “internal read”, i.e. it is trying to read from a string. My guess is that it is the ‘-m’ in your command line. The option is ‘-wf M’ where M is a number; ‘-m’ is not a valid option.

        Elias


_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to