No, I don't think that for this system GGA+U or hybrids are appropriate.

Is your supercell large enough (~100 atoms) ??
Did you relax the atomic positions ??
Maybe the Cd sits in a different position ??

Am 02.02.2015 um 20:09 schrieb Marcelo Barbosa:
Dear all,

I need to calculate the EFG and ETA in a Cd impurity in Ga2O3 but using the 
usual GGA method gives me an ETA near 1 when experimentally it is known to be 
between 0.0 and 0.1.
I would like then to ask what is the best method to get good EFG and ETA values 
in such a case:
- use GGA+U for the 3d orbitals of Ga and 4d orbitals of Cd?
- use onsite-exact-exchange / hybrid functionals for those orbits?
- use hybrid functionals for all electrons?
or do you think these different options won’t change the ETA?

Best regards,
Marcelo Barbosa
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


--
Peter Blaha
Inst.Materials Chemistry
TU Vienna
Getreidemarkt 9
A-1060 Vienna
Austria
+43-1-5880115671
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to