Did you use run calculation with the -orb flag: runsp_lapw -orb

On Wed, 25 Nov 2015, Jihoon Park wrote:

Dear users,

I have tried to add GGA+U with different U values, but always get the same 
total energies.
The steps that I did are as follows:
1. Do spin-polarized calculation.
2. setup spin-orbit coupling and orbital pot (DFT+U) together.
3. Run

This procedure is very simple and straightforward, but I don't know why there 
is no difference for different U values.
Would you please let me know what mistakes I have been making?


All my best,
Jihoon Park