With the onsite hybrids (-eece): -In the interstitial region, case.r2v contains the total XC potential since the hybrid method is not applied in this region.
-Inside the spheres, case.r2v does not contain the hybrid term coming from E_{x}^{HF}-E_{x}^{semilocal} (see formula in Sec. 4.5.7 of the UG). This additional term missing in case.r2v should be small because it is multiplied by alpha=0.2 and there is some cancellation between the HF and semilocal components. In addition, this hybrid term in the potential is applied only to electrons of a given angular momentum (d or f), whil it zero for the other electrons. F. Tran On Thu, 18 Feb 2016, Majid Yazdani wrote:
Dear Prof. Blaha Thanks very much for you reply. > Only one word of warning: For a hybid-functional like B3PW91, there is an additional orbital dependent HF-potential, which is of course NOT plotted in your procedure (and which cannot be plotted directly in WIEN2k). Is there any way to know the portion of additional orbital dependent HF-potential?Is this portion high or small? On Thu, Feb 18, 2016 at 11:24 AM, Peter Blaha <pbl...@theochem.tuwien.ac.at> wrote: Your procedure is fine, at least for semilocal potentials (LDA, GGA). V-coul is much larger near the atomic cores, but far from the nucleii in the interstitial region Vxc and Vcoul have the same order of magnitude. Only one word of warning: For a hybid-functional like B3PW91, there is an additional orbital dependent HF-potential, which is of course NOT plotted in your procedure (and which cannot be plotted directly in WIEN2k). On 02/17/2016 06:55 PM, Majid Yazdani wrote: Dear Wien2k authors and users I’m interested to calculate total, Coulomb, and XC potential using wien2k code. I performed the scf calculations using B3PW91 with alpha=0.2 using following command: I expected that the range of Coulomb potential must be very higher than XC potential and XC term is very little. However, after potential calculations I saw that between atoms the range of Coulomb potential is very close to XC potential. A small positive Coulomb potential and small negative XC potential leads to the very small negative total potential. Could you help me please to know that whether are my calculations true or not? Is this correct that XC and Coulomb terms are in the same range? _______________________________________________ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html -- P.Blaha -------------------------------------------------------------------------- Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna Phone: +43-1-58801-165300 FAX: +43-1-58801-165982 Email: bl...@theochem.tuwien.ac.at WIEN2k: http://www.wien2k.at WWW: http://www.imc.tuwien.ac.at/staff/tc_group_e.php -------------------------------------------------------------------------- _______________________________________________ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
_______________________________________________ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html