You don't need HDLOs for Cs.
This is more critical for 4f (5f) systems and maybe for elements with d-states, but not for sp-elements.

Used -lnvs 6 or 8 though !

On 06/19/2018 04:02 AM, Dr. K. C. Bhamu wrote:
Thanks Gavin,


I see, when I use -lnvs x (x=4 to 10 in the interval of 1) the HDLO/lvns warning does not disappear.


When I reduce rmt of Cs from 2.5 to 2.3 these warning goes but then this small rmt will cost computational time.


As per UG, I see how to add HDLO.

below is my case.int <http://case.int> file for the case and first two atoms are Cs for which I am getting a warning:

----------------------------case.in1 only for first two atoms-------------------------------------------------------
WFFIL  EF= 0.50000       (WFFIL, WFPRI, ENFIL, SUPWF)
  7.00     10   6   ELPA pxq hm (R-MT*K-MAX,MAX L IN WF,V-NMT,lib,gridshape,hm/lm)   0.30    6  0      (GLOBAL E-PARAMETER WITH n OTHER CHOICES, global APW/LAPW)  2    0.30     0.0000 CONT 1   >> As per UG, I can add HDLO here, i.e. replace 1 by 2   (as HDLOs can be applied to only one state)
  2   -5.08     0.0001 STOP 1
  0    0.30     0.0000 CONT 1
  0   -1.66     0.0010 CONT 1
  1    0.30     0.0000 CONT 1
  1   -0.66     0.0010 CONT 1
  0.30    6  0      (GLOBAL E-PARAMETER WITH n OTHER CHOICES, global APW/LAPW)  2    0.30     0.0000 CONT 2 >> As per UG, I can add HDLO here, i.e. replace 1 by 2
  2   -5.08     0.0001 STOP 1
  0    0.30     0.0000 CONT 1
  0   -1.66     0.0010 CONT 1
  1    0.30     0.0000 CONT 1
  1   -0.66     0.0010 CONT 1
  0.30    4  0      (GLOBAL E-PARAMETER WITH n OTHER CHOICES, global APW/LAPW)

But after adding HDLOs and increasing value of lvns, I am these warning still persists.


Could you please confirm whether I am adding HDLOs in wrong way or the only option to remove these warnings are the reduction in rmt?

Kind regards
Bhamu


On Tue, Jun 19, 2018 at 5:13 AM, Gavin Abo <gs...@crimson.ua.edu <mailto:gs...@crimson.ua.edu>> wrote:

    For LVNS, see section "5.1.3 Job control for initialization
    (init_lapw)" on page 63 in the WIEN2k 17.1 usersguide [
    http://susi.theochem.tuwien.ac.at/reg_user/textbooks/usersguide.pdf
<http://susi.theochem.tuwien.ac.at/reg_user/textbooks/usersguide.pdf> ]. There it looks like you just need to add the '-lvns L' switch to
    your init_lapw command.

    For example, if L = 4:

    init_lapw -b -lvns 4

    For HDLO, see the case.in1 description in section "7.5.3 Input" on
    page 127 in the WIEN2k 17.1 usersguide.  It doesn't look like there
    is a batch mode option for that.  Though, if you know a scripting
    language, you could try writing your own scripting code for doing that.

    On 6/18/2018 4:54 PM, Dr. K. C. Bhamu wrote:
    Dear Wien2k Users,

    For elements with high "Z", we frequently get below warnings:

    atom 1 has a large sphere , consider setting HDLOs and/or larger LVNS

    I am wondering if someone knows how to set these values in batch mode.


    Kind regards
    Bhamu

    _______________________________________________
    Wien mailing list
    Wien@zeus.theochem.tuwien.ac.at <mailto:Wien@zeus.theochem.tuwien.ac.at>
    http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
    <http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien>
    SEARCH the MAILING-LIST at:
    http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
    <http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html>




_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


--

                                      P.Blaha
--------------------------------------------------------------------------
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300             FAX: +43-1-58801-165982
Email: bl...@theochem.tuwien.ac.at    WIEN2k: http://www.wien2k.at
WWW:   http://www.imc.tuwien.ac.at/TC_Blaha
--------------------------------------------------------------------------
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to