Not sure if it helpful or not, but should it be, there was a thread of posts related to force minimization back in March of 2021, in it you can see it references a "README_Constraints.pdf":

https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg20952.html

The README_Constraints.pdf appears to be identical to the "Constraint structure optimization (pdf)" link which is on the WIEN2k webpage among other structure optimization documentation (Structure optimization-notes, Notes on the mixer, ...):

http://www.wien2k.at/reg_user/textbooks/

Kind Regards,

Gavin
WIEN2k user

On 7/3/2022 1:26 PM, shamik chakrabarti wrote:
Dear Wien2k users,
                              I have a basic question. When the force at each atom is calculated & compared with the cut-off values ( ~ 2 mRy/a.u.) & if the force at each atom is found to be larger than the cut-off values, the shifting of atomic coordinates occurs for searching equilibrium. Now, here the question arises:

*How did the algorithm know which way to proceed? *

For volume optimization, we fed the data of the lattice parameters & the code performs the calculation on the same. But during force minimization, we did not feed the values of atomic coordinates apart from the initial values, still the code search for new atomic coordinates spontaneously? Is it AI?

Looking forward to your reply

with regards,

--
Dr. Shamik Chakrabarti
Research Fellow
Department of Physics
Indian Institute of Technology Patna
Bihta-801103
Patna
Bihar, India
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien