I have probably overlooked in your conversion when you mentioned whether you were using a shifted or non-shifted k-mesh; If you happened to have used a shifted k-mesh in yourperovskites calculation, then you might try the calculation again with a non-shifted k-mesh during "x kgen":

https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg15445.html
https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg19427.html
https://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/msg15445.html

Kind Regards,

Gavin
WIEN2k user

On 9/10/2022 4:20 AM, Dr. K. C. Bhamu wrote:
Thanks Prof. Marks for your suggestions.

My system is non-sp and non-SO type.

I didn't do any mistake with k-path as Its a cubic system and its brillouin zone is very simple.

I do agree with the k-mesh as with very fine mesh narrow band gap systems may show metallic character.
In one of my case it is happening.


But in a separate case where I didn't change the k-mesh after SCF for band structure calculation, the band structure should show the same band gap as I am getting with the grep command. No?

Thanks
Bhamu

On Sat, Sep 10, 2022, 3:11 PM Laurence Marks <laurence.ma...@gmail.com> wrote:

    I can think this can occur in numerous ways, all a minor mistake:

    1. You forgot to include -orb when you did the bands.
    2. You had too small a k-mesh for the scf, the fine one for the
    bands shows a metal.
    3. Your grep showed just the "up" spin, not both.
    4. You did not fully converge.
    5. You forgot -so in the band.
    6. You have a mistake in your k-mesh for the bands.
    7. Something else similar.

    Just my guesses, I suggest you check carefully. Number 7 is most
    likely.

    --
    Professor Laurence Marks
    Department of Materials Science and Engineering, Northwestern
    University
    www.numis.northwestern.edu <http://www.numis.northwestern.edu>
    "Research is to see what everybody else has seen, and to think
    what nobody else has thought" Albert Szent-Györgyi

    On Fri, Sep 9, 2022, 10:45 PM Dr. K. C. Bhamu
    <kcbham...@gmail.com> wrote:

        Dear Users

        Greetings,

        I am trying to compute the band structure of some ABX3
        perovskites systems with Wien2k_19.2 compiled with intel
        compilers.
        When I grep the band gap from case.scf, I am getting some
        values (~0.7eV) while when I plot the band structure, the VBM
        is significantly crossing the Fermi level and the gap between
        CBM and VBM is much lesser than the one I grepped from
        case.scf file.
        In some case, VBM and VBM are overlapping while case.scf file
        is showing a clear band gap.

        I have updated Fermi energy in case.insp files.

        I never faced such an issue in the past.

        I am wondering if you would like to help me out.

        Regards
        Bhamu
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to