Robert Reif <[EMAIL PROTECTED]> writes: > For whatever reason Microsoft decided not to use the standard > equations like the rest of the world. I assume it was to eliminate > the need for floating point calculations. Actually you could use the > same equation that the generated the table to go from dB to amp but > you can't use an equation to go the other way around because of the > weird roundoff errors that result from using a lookup table.
Yes, but does that really make a difference for real apps? Do we really need to duplicate the roundoff errors? -- Alexandre Julliard [EMAIL PROTECTED]