A bit pricey for $695.
Internal power supply, 48V, 1A. 4 Watts max.
Unclear on load capabilty. 48Vx1amp=48W.
Not to useful, when it integrates power and ethernet, if it doesn't support
passing VLAN/large packets.
The added AC reboot recepticle was a good idea. Without it, it prevents the
Reboot device to be used to reboot a PC based router. What good is it to
save on reboot device cost, if two are needed, one for DC one for AC? So it
solves that problem.
However, for a unit to support end user CPEs, bothAC and DC support really
not needed. ONe or the other will work. The only requirement is for it to
cost under a $100! It would be nice if the reboot device supported two
devices. That would then allow rebooting both home gateway and CPE radio.
Tom DeReggi
RapidDSL & Wireless, Inc
IntAirNet- Fixed Wireless Broadband
----- Original Message -----
From: <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>; "'WISPA General List'" <wireless@wispa.org>
Sent: Wednesday, November 09, 2005 8:06 PM
Subject: RE: [WISPA] IP based Remote Reboot
Blair
I think this will do what you need tell them Tony front Demarc sent you:
http://www.remotedatacom.com/pages/KABU.html
Sincerely, Tony Morella
Demarc Technology Group, A Wireless Solution Provider
Office: 207-244-9068 Fax: 207-433-1008
http://www.demarctech.com
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Blair Davis
Sent: Tuesday, November 08, 2005 11:22 PM
To: WISPA General List
Subject: Re: [WISPA] IP based Remote Reboot
Well, I guess there is no reasonably priced unit out there that will do
what
I need and fit in the space allowed.
The comments on the list have shown me that there may be a demand for a
unit
like this. I have decided to build my own. I have also decided to make
it
available to others who might need it.
As part of this process, I am posting the planned specs and I am asking
for
additional ideas for features.
Specs:
Hardware
10baseT ethernet port for communication.
1-4 pair of RJ-45 pass thru jacks with lines 4 and 5 switched.
Each pass thru jack pair is independently switched
Relay(s) rated for up to 48VDC at 3A
Power available monitor for switched jack(s) Unit powered via 5-12VDC
Software
Setup and controlled via web browser or telnet Static IP with subnet and
gateway Programmable ping monitor for each relay Selectable 'keep alive'
/
'I am here' ping Adjustable power off delay Adjustable power off time
Several things I am undecided about adding are:
Email notification of ping failure
Email notification of power available status change Programmable,
repeatable
by time and date switching
(this requires a real time clock and/or automatic synchronization with
a
time server and might increase the costs)
One thing I will not add:
Switching 110/220AC. This would add many requirements for testing and
considerable legal liability.
The price should be under $100 each.
Questions?
Comments?
Interest?
--
Blair Davis
West Michigan Wireless ISP
269-686-8648
--
WISPA Wireless List: wireless@wispa.org
Subscribe/Unsubscribe:
http://lists.wispa.org/mailman/listinfo/wireless
Archives: http://lists.wispa.org/pipermail/wireless/
--
WISPA Wireless List: wireless@wispa.org
Subscribe/Unsubscribe:
http://lists.wispa.org/mailman/listinfo/wireless
Archives: http://lists.wispa.org/pipermail/wireless/
--
No virus found in this incoming message.
Checked by AVG Free Edition.
Version: 7.1.361 / Virus Database: 267.12.8/163 - Release Date: 11/8/2005
--
WISPA Wireless List: wireless@wispa.org
Subscribe/Unsubscribe:
http://lists.wispa.org/mailman/listinfo/wireless
Archives: http://lists.wispa.org/pipermail/wireless/