A bit pricey for $695.

Internal power supply, 48V, 1A. 4 Watts max.

Unclear on load capabilty. 48Vx1amp=48W.

Not to useful, when it integrates power and ethernet, if it doesn't support passing VLAN/large packets.

The added AC reboot recepticle was a good idea. Without it, it prevents the Reboot device to be used to reboot a PC based router. What good is it to save on reboot device cost, if two are needed, one for DC one for AC? So it solves that problem.

However, for a unit to support end user CPEs, bothAC and DC support really not needed. ONe or the other will work. The only requirement is for it to cost under a $100! It would be nice if the reboot device supported two devices. That would then allow rebooting both home gateway and CPE radio.

Tom DeReggi
RapidDSL & Wireless, Inc
IntAirNet- Fixed Wireless Broadband


----- Original Message ----- From: <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>; "'WISPA General List'" <wireless@wispa.org>
Sent: Wednesday, November 09, 2005 8:06 PM
Subject: RE: [WISPA] IP based Remote Reboot


Blair

I think this will do what you need tell them Tony front Demarc sent you:
http://www.remotedatacom.com/pages/KABU.html

Sincerely, Tony Morella
Demarc Technology Group, A Wireless Solution Provider
Office: 207-244-9068 Fax: 207-433-1008
http://www.demarctech.com



-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Blair Davis
Sent: Tuesday, November 08, 2005 11:22 PM
To: WISPA General List
Subject: Re: [WISPA] IP based Remote Reboot

Well, I guess there is no reasonably priced unit out there that will do what
I need and fit in the space allowed.

The comments on the list have shown me that there may be a demand for a unit like this. I have decided to build my own. I have also decided to make it
available to others who might need it.

As part of this process, I am posting the planned specs and I am asking for
additional ideas for features.

Specs:

Hardware

10baseT ethernet port for communication.
1-4 pair of RJ-45 pass thru jacks with lines 4 and 5 switched.
Each pass thru jack pair is independently switched
Relay(s) rated for up to 48VDC at 3A
Power available monitor for switched jack(s) Unit powered via 5-12VDC

Software

Setup and controlled via web browser or telnet Static IP with subnet and
gateway Programmable ping monitor for each relay Selectable 'keep alive' /
'I am here' ping Adjustable power off delay Adjustable power off time

Several things I am undecided about adding are:

Email notification of ping failure
Email notification of power available status change Programmable, repeatable
by time and date switching
(this requires a real time clock and/or automatic synchronization with a
time server and might increase the costs)

One thing I will not add:

Switching 110/220AC.  This would add many requirements for testing and
considerable legal liability.

The price should be under $100 each.

Questions?

Comments?

Interest?

--

Blair Davis
West Michigan Wireless ISP
269-686-8648










--
WISPA Wireless List: wireless@wispa.org

Subscribe/Unsubscribe:
http://lists.wispa.org/mailman/listinfo/wireless

Archives: http://lists.wispa.org/pipermail/wireless/

--
WISPA Wireless List: wireless@wispa.org

Subscribe/Unsubscribe:
http://lists.wispa.org/mailman/listinfo/wireless

Archives: http://lists.wispa.org/pipermail/wireless/


--
No virus found in this incoming message.
Checked by AVG Free Edition.
Version: 7.1.361 / Virus Database: 267.12.8/163 - Release Date: 11/8/2005



--
WISPA Wireless List: wireless@wispa.org

Subscribe/Unsubscribe:
http://lists.wispa.org/mailman/listinfo/wireless

Archives: http://lists.wispa.org/pipermail/wireless/

Reply via email to