We are working on deploying a pair of M5 dishes on our network bridging
point a and point b.  When we plug in the network to the dishes, the
ping times climb to 1200+ms on side b of the bridge, and equipment local
to the side b of the bridge, and time out after two or more hops,
essentially bringing the whole network down.  We can ping point to point
with no traffic at 2ms.  We are replacing a pair of existing bridges
from another manuf. and not seeing this issue over these.  Signal is
-53dbm on both sides.  -85 noise floor.  Any ideas?

 